HF-MBR-6-PVDF

Product Line Description

2.0 to 3.0 Cubic Meter per Day (m³/d) Water Production Flow Membrane Bioreactor (MBR).
Membrane Bioreactor (MBR) is a new type of wastewater treatment technology that combines high-efficiency membrane separation technology with biochemical technology. The hollow fiber membrane module directly performs solid-liquid separation in the biochemical pool, replacing the secondary sedimentation tank in the activated sludge method, and effectively achieves the purpose of muddy water separation. The high-efficiency retention effect of the membrane allows the nitrifying bacteria to be completely retained in the bioreactor, so that the nitrification reaction can be smoothly carried out, the ammonia nitrogen can be effectively removed, the sludge can be avoided, and the macromolecular organic matter which is difficult to degrade can be retained at the same time, and the residence time of the reactor is maximized. After applying MBR technology, the main pollution removal rate can reach: COD≥93%, the suspended solids and turbidity are close to zero, the water quality is good and stable, and it can be directly reused to realize the sewage resource.

Specifications
Brands HUAMO
JMCC
Membrane Area 6 m²
Length 1000 mm
Width 655 mm
Thickness 50 mm
Outlet DN25
Air Inlet NA/DN25
Weight 6 kg
Fitting Material Acrylonitrile Butadiene Styrene (ABS)
Unplasticized Polyvinyl Chloride (UPVC)
Parameter
Membrane Material Polyvinylidene Fluoride (PVDF)
Intercepting Aperture < 0.2 µm
Hollow Fiber Inner 1.0 mm
Hollow Fiber Outer 2.4 mm
Water Turbidity < 1 NTU
Effluent Suspended Solids < 1 mg/L
Life 3 to 5 year
Packaging Material Epoxy
Polyurethane (PU)
Process
Temperature Range 1 to 45 ºC
Potential of Hydrogen (pH) Range 2 to 13 pH
Water Production Flow 2.0 to 3.0 m³/d
Maximum Transmembrane Pressure Difference -0.08 MPa
Outlet Way Negative Pressure Suction
Running Way (Working) 8 min
Running Way (Stop) 2 min
Chemical Sterilization Pharmacy Sodium Hypochlorite
Chemical Cleaning Cycle 6 to 12 months
Chemical Cleaning Pharmacy Citric Acid
Sodium Hypochlorite
Note
  1. The technical parameters and descriptions listed in the table are production standard values for reference. If there are special requirements, they can be adjusted accordingly.
  2. The water production flow in the table refers to the design reference flux when the product is used for sewage treatment.